Part Number Hot Search : 
1N5369B PB0168 SJ010889 M013TR PST3840 X25L64 RELAYS SF38G
Product Description
Full Text Search
 

To Download MAX-504-1205 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com telecom mtc series 400, 500 watts multiple output max-400 max-500 mtc-500 featuring: over 3.5 watts/in 3 power density 80% overall efficiency vmebus and multibus ii system compatibility meets international safety agency requirements all outputs regulated 1% high peak currents for motor starting system air or self-cooling options ac automatic line selection option model pwr output #1 output #2 output #3 output #4 max-403-0512 400 +5v @ 70a +12v @ 10/16a pk -12v @ 6a max-503-0512 500 +5v @ 80a +12v @ 10/16a pk -12v @ 10a MAX-504-1205 500 +5v @ 80a +12v @ 10/16a pk -12v @ 10a 5.2v @ 2a max-504-1212 500 +5v @ 80a +12v @ 10/16a pk -12v @ 10a 12v @ 2a max-504-1224 500 +5v @ 80a +12v @ 10/16a pk -12v @ 10a +24v @ 2a max-504-1252 500 +5v @ 80a +12v @ 10/16a pk -5.2v @ 10a 12v @ 2a standard max series vmebus and multibus compatibility is only one feature of this series. you?l find switchers to power up to 80 amps of logic and four hard disk drives ?with up to 16 amps peak current to meet peripheral startup needs. you?l find the outputs you need for isdn, lan, t1 applications and for standard voice and data networks. high-current auxiliary outputs provide regulation characteristics for proper operation of line drivers, network inter- faces, and rs232-type outputs. and, you can upgrade power output by 25% without redesigning for a larger power supply. model pwr output #1 output #2 output #3 mtc-503-0512 500 +5v @ 70a +12v @ 10a -12v @ 10a mtc-503-0515 500 +5v @ 70a +15v @ 8a -15v @ 8a option v option c option f
condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com 400, 500 watts 11.5?x 5x 2.5 max-400, 500 mtc-500 specifications: all models input ac input: 90-132 vac/180-264 vac, 47 to 63 hz. user selectable. see option ??for automatic line selection. internally fused for 12 a. inrush: cold start ac current is less than 80 a at 115 vac and 20 a at 230 vac. limited by thermistor. holdup time: 16 ms minimum after removal of power, at nominal line, full load. efficiency: 80% typical. brownout protection: holds regulation to 85 vac or 170 vac. output adjustability: user adjustable ?% minimum. line & load reg: ?% over ac input range and 0 to 100% load change. output #1 requires minimum load of 10%. ripple & noise: less than 1% p-p or 100 mv, whichever is greater. remote sense (output #1) : compensates for 250 mv total line drop. open sense lead protection. temperature coefficient: 0.02% per degree c. stability: 0.1% over 8 hours after 30 minutes warm-up. transient response (output #1) : output voltage returns to within 1% in less than 500 ? for a 50% load change. peak transient does not exceed 5%. overload protection: all outputs are protected against overload and short circuit. automatic recovery upon removal of fault. overvoltage protection (output #1) : protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 136% of nominal. remote inhibit: contact closure to the negative sense line drops output power to nominal zero. reverse voltage: protected against reverse voltage up to supply current rating. environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: 0 to 50? at full ratings. derate to half power at 70?. safety agencies: most models are approved to ul1950; csa 22.2 #234; iec 950 and t?v en60950, class 1 selv., ce 72/23/eec/93/68eec (low voltage directive). conducted rfi: meets fcc part 15, subpart j, class a; en55022 class b; cispr 22 class b. cooling: 30 cfm required to achieve full ratings. output isolation: isolated from ground 50 vdc. options: option ?? ac auto-range: automatically selects proper ac line voltage range to enable power operation at either 115 or 230 vac without user intervention. option ?? cover: limits contact with power supply interior. option ?? fan/cover assembly: cover with integral ball-bearing fan provides proper cooling to achieve full ratings at 50? ambient temperature. function 115 vac 230 vac connectors input select short open 0.250 male fastons tb1- line line 1 tb1- neutral line 2 tb1- safety ground safety ground ac input function location notes connector output #1 terminal marked +v main output terminal marked com rtn (common) output #2 tb2-3 tb2-4 rtn (common) output #3 tb2-5 tb2-4 rtn (common) output #4* tb2-1 (+) (if provided) tb2-2 (? dc output barrier strip #6-32 screws 3.8?centers bus bars #1/4-20 screws barrier strip #6-32 screws 3/8 centers. function location notes connector remote sense j1-1 (+s) output #1 sense j1-2 (-s) output #1 sense rtn ac power fail or j1-3 (pf) reference to j1-2 dc power good* inhibit j1-4(1h) short to j1-2 status and control amp mta type #640456-4 pin header (locking) *rtn connected to common only if output is polarized in product selection chart *optional function option ?? dc power good: provides a ttl ??open collector when output #1 is above 4.6 v nominal. not available if option ??is selected. option ?? ac power fail: provides ttl ?? 5 ms before output voltage goes out of regulation band upon loss of ac power. vmebus compatible, provides 48 ma sink current capability. not available if option ??is selected. option ?? fan/cover assembly: low profile, end venting cover with integral ball-bearing fan. consult factory for other available options. max, mtc-500 with option f 5.2 lbs - 2.4 kgs max, mtc-500 4.5 lbs - 2.0 kgs dimensions: inches millimeters (l) (n) ( )


▲Up To Search▲   

 
Price & Availability of MAX-504-1205

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X